• Fxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite Insulator
  • Fxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite Insulator
  • Fxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite Insulator
  • Fxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite Insulator
  • Fxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite Insulator
  • Fxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite Insulator

Fxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite Insulator

Certification: ISO9001
Transport Package: Packing Suitable for Sea Shipments
Specification: POLYMER HOUSED ZINC OXIDE ARRESTER
Trademark: XN
Origin: China
Samples:
US$ 12/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
FXBW4-110/100
HS Code
8535400000
Production Capacity
2000PCS/Month

Product Description

Main Technical Parameter of Pin Composite Insulator
 
Design code Rated Voltage
(KV)
Rated
mechanical
stretch load
(kn)
Structure Height
(mm)
Minimum
arcing
distance (mm)
Minimum nominal
creepage distance
(mm)
Diameter
of shed D(mm)
Lightning impulse
withstand voltage
[peak]≥(KV))
Power frequency
withstand voltage
(wet)≥(KV)
FPQ-10/4T20 10 4 215 125 280 148/118 75 42
FPQ4-10/5T20 10 5 250 165 460 148/118 105 42
FPS-105/5 10 5 250 180 380 90 105 42
 
 
Main Technical Parameter of Suspension Composite Insulator
 
Design code Rated Voltage
(KV)
Rated
mechanical
stretch load
(kn)
Structure Height
(mm)
Minimum
arcing
distance (mm)
Minimum nominal
creepage distance
(mm)
Lightning impulse
withstand voltage
[peak]≥(KV))
Power frequency
withstand voltage
(wet)≥(KV)
Structure of
connected marks
FXBW4-10/70 10 70 400 200 480 75 42 16
FXBW4-10/100 10 100 450 200 480 75 42 16
FXBW4-35/70 35 70 650 450 1320 230 95 16
FXBW4-35/100 35 100 720 520 1600 230 95 16
FXBW4-6670 66 70 900 710 2140 410 185 16
FXBW4-66/100 66 100 940 710 2140 410 185 16
FXBW4-110/100 110 100 1240 1000 3315 550 230 16
FXBW4-145/120 145 120 1480 1240 4123 725 355 16
FXBW4-220/100 220 100 2240 1900 6300 1000 935 16
FXBW4-220/160 220 160 2240 1900 6300 1000 935 16
FXBW4-330/160 330 160 2990 2600 9075 1425 570 16
FXBW-12/70 12 70 390 180 460 105 42 16
FXBW-15/70 15 70 445 225 620 105 42 16
FXBW-24/70 24 70 450 235 635 150 65 16
FXBW-24/70 24 70 450 265 643 150 65 16
FXBW-28/70 28 70 560 380 1250 230 95 16
FXBW-33/70 33 70 560 380 1130 230 95 16
FXBW-35/70 35 70 550 390 850 230 95 16
FXBW-36/70 36 70 580 380 1250 230 95 16
FPQ2-24/4 24 4 310 180 645 150 65 16
FPQ2-36/5 36 5 620 460 1160 230 95 16
 

Main Technical Parameter of Post Composite Insulator
 
Design code Rated Voltage
(KV)
Rated
mechanical
stretch load
(kn)
Structure Height
(mm)
Minimum
arcing
distance (mm)
Minimum nominal
creepage distance
(mm)
Diameter
of shed D(mm)
Lightning impulse
withstand voltage
[peak]≥(KV))
Power frequency
withstand voltage
(wet)≥(KV)
FZSW-10/4 10 4 215 125 290 100/90 75 42
FZSW-20/8 20 8 400 320 750 142 150 65
FZSW-35/6 35 6 450 360 946 148/118 185 95
FZSW-66/6 66 6 760 630 1886 160/130 410 185
FZSW-66/8 66 8 760 630 2010 220/190 410 185
FZSW-
110/10
110 10 1220 1080 3530 220/190 500 230
FZSW-220/10 220 10 2440 2200 7060 220/190 1000 395

 
Main Technical Parameter of Composite Insulator for electric railway
 
Design code Rated Voltage
(KV)
Rated
mechanical
stretch load
(kn)
Structure Height
(mm)
Minimum nominal
creepage distance
(mm)
Lightning impulse
withstand voltage
[peak]≥(KV))
Power frequency
withstand voltage
(wet)≥(KV)
Structure of
connected marks
FQX1-25 25 60 650 1400 270 130 aa
FQX2-25 25 20 840 1400 270 130 bb
FQX3-25* 25 20 930 1400 270 130 bb
FQX3-25* 25 20 760 1400 270 130 ac
FQX4-25 25 20 806 1400 270 130 gh
FQX5-25 25 60 645 1400 270 130 af
FQE3-25* 25 60 640 1400 270 130 ff
FQE4-25* 25 20 836 1400 270 130 gc
FQE5-25* 25 20 695 1400 270 130 de
FQE5-25 25 20 695 1400 270 130 gi




Compostie Insulator

Application
The composite insulator line of XINNENG includes line insulators comprised of line rod, line post, traction line type and line spacer, station insulators comprised of outdoor solid core, indoor solid core type, post and tension hollow post and tension rod, insulatig bushing comprised of oil impregnated paper condenser wall bushing and dry type condenser wall bushing. Moreover, shed booster for station insulation, feeding rod for locomotive and dry type polymer current transformer are also available.

The shed housing polymer for XINNENG composite insulator is prepared using specific composition mixing developed by XINNENG experts for years, contributing the highest grade of tracking and corrosion resistance in conformance with IEC standard, which shows no apparent degradation after artificial accelerate ageing for 1000h and natural exposure test for 15 years.

The XINNENG insulator are manufactured with unique one-piece injection molding technique, excluding possibility of interface feakdown. Amain frouble which may destroy the normal operation of insulators. The unique gluing connection of line rod insulator with metal getting keeps FRP rod intact, providing the highest reliability of insulator in respect of its mechanical performance with practically no degradation even in environment of high temperature or severe cold.

The composite insulator, characteristic of small size, light weight, high mechanical strength, shatter-free, easy handling, well shock-resistance, pollution-resistance and minor maintenance, grows fast as a new generation of insulator.

Insulator with specific parameters other than those listed hereafter is required by customer, it can be supplied by technical agreement. If any insulator of other app;ication is needed, XINNENG is willing to proceed cooperative development to meet utmost the customer demand.



Normal service conditions
a) Ambient air temperature within the range of -40ºC to +50ºC.
b) Altitude not exceeding 1500m.
c) Frequency of the A.C. power supply not less than 48Hz and not exceeding 62Hz.
d) Maximum wind speed not exceeding 35m/s.
e) Earthquake intensity not exceeding 8 degrees.


Characteristics:
Small volume and light weight, easy to transport and install.
The superior in performance and high intensity mechanical enhance reliability of power line.
Extraordinary hydrophobic and resistance to contamination.
Long-duration resistance aging and leakage tracking.

Fxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite Insulator

Fxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite Insulator



Fxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite InsulatorFxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite InsulatorFxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite InsulatorFxbw4-110/100 Silicon Rubber Housed High Voltage Suspension Composite Insulator


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now